Start with the load, not the capacitance value. A suitable part must satisfy energy, voltage drop, temperature, mechanical and qualification requirements together.
Engineering fundamentals
For constant current, estimate C = It / (Vstart − Vmin − I·ESR). If the denominator is not positive, select a lower-resistance part or revise the voltage window.
Selection and validation
Send your load current, hold-up time, rail voltage, size limit and quantity for an application-led review.
From concept to component
A calculation or general guide is not a substitute for a confirmed datasheet. Bring the load profile, usable voltage, operating environment and mechanical constraints into your product review.